Post Offer Free
Gloria Steel
Gloria Steel  

Gold Index: 12773

You are here: home  > Others  > Technical conditions for plates of SA387Gr11CL2 HIC

Technical conditions for plates of SA387Gr11CL2 HIC 

Price: 2000.0~5000.0 USD 
Payment Terms: T/T,L/C 
Place of Origin: Guangdong, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: SA387Gr11CL2
Production Capacity: 3000~5000T
Delivery Date: 30 days
Means of Transport: Ocean
Packing: Standard seaworthy export p...

The technical conditions apply to plates of SA387Gr11CL2 HIC with thickness range 10mm-120mm use of CNPC's Karamay project.

Technical conditions for plates of SA387Gr11CL2 HIC

 

1.       Scope

The technical conditions apply to plates of SA387Gr11CL2 HIC with thickness range 10mm-120mm use of CNPC's Karamay project.

2.       Adopt standard:

ASME SA387/SA387M Specification for pressure vessel plates, alloy steel, Chromium-Molybdenum

ASME SA20/SA20M Standard Specification for General Requirements for Steel Plates for Pressure Vessels

ASME SA370 Standard Test Methods and Definitions for Mechanical Testing of Steel Products

3.       Dimension, Shape, Weight and Permissible Deviation

The dimension, shape, weight and permissible deviation shall meet the requirements of ASME SA20/SA20M.

The thickness toleration: -0/+3.5mm

4.       Technical conditions

4.1   Chemical composition (Ladle analysis)

The chemical composition of plates shall be accordance with the following table 1.

Table 1 Chemical composition (Ladle analysis)

Grade

Thickness

mm

C

Si

Mn

P

S

Ni

Cu

SA387Gr11CL2

HIC

Ladle analysis

0.05- 0.17

0.50- 0.80

0.40- 0.65

Max 0.010

Max 0.010

Max 0.20

Max 0.20

Product analysis

0.04- 0.17

0.44- 0.86

0.35- 0.73

Max 0.010

Max 0.015

Max 0.25

Max 0.20

 

Grade

Thickness

mm

Cr

Mo

Sb*

Sn*

As*

[H]*

SA387Gr11CL2

HIC

8-12.5

1.00- 1.50

0.45- 0.65

Max 0.003

Max 0.010

Max 0.010

Max 2ppm

12.6-76

0.94- 1.56

0.40- 0.70

Max 0.003

Max 0.010

Max 0.010

Max 2ppm

Note:

1)      Si+Mn =< 1.2%

2)      Mark "*" just record the value.

 

4.2   Steel making process: EAF+LF/VD

4.3   Mechanical properties

The mechanical properties of SA387Gr11CL2 HIC shall meet the requirement as table 2&3.

Table 2 Tensile properties

Thickness mm

Yield strength MPa

Tensile strength MPa

Elongation %

Bend test

8-100

Min 310

515-690

Min 22

180C un-cracked

 

4.4   Impact properties

Impact test in the longitudinal and transverse for plates of SA387Gr11CL2 HIC shall meet the requirements per table 3.

Table 3 Impact properties

Charpy-V Impact test

Test temp.

Celsius degree

Transverse

Average impact energy

-20C

Min 55J

 

4.5   Hardness: Max 22HRC

4.6   SWHT: Simulated Post-Weld Heat Treatment of Mechanical Test Coupons shall be prepared in 600+/-10 C with min.5 minute per each mm of thickness.

4.7   NACE MR0175/ISO 15156-2 / Annex B.5 / Test method NACE TM0284 in solution-A sour service (CLR =< 5% & CTR =<5% & CSR =< 2% shall be reported)

4.8   Surface quality

The surface quality of plates shall be accordance with ASTM A20/A20M.

4.9   Ultrasonic inspection

Plates shall be ultrasonic inspected per ASTM A578/A578M level B.

4.10    Test method and inspection rules

Test items, sampling quantity, sampling method and test method shall conform to table 4.

Table 4 Test items for plates

Test item

Quantity, Piece

Sampling method

Test method

Sampling conditions

Ladle analysis

1 (per furnace)

ASTM A20/A20M

ASME SA370

/

Tensile test

1 (per rolled pc)

ASTM A20/A20M

ASME SA370

SWHT

Charpy-V impact test at -20C

3 (per rolled pc)

ASTM A20/A20M

ASME SA370

Hardness

1 (per rolled pc)

GB/T2975

GB/T 230.1

Product analysis

1 (per rolled pc)

ASTM A20/A20M

ASME SA370

+N

Ultrasonic test

Each product pc

ASTM A578/A578M

HIC test

See 5.HIC

NACE TM0284

NACE TM0284

SWHT

 

5.       HIC sampling method: Per heat number/ thickness/ heat treatment rules combine one group.

6.       Package, marking and certificate

Package, marking and certificate shall conform to A20.

7.       The third party inspection

The chemical composition, tensile test and Charpy -V impact test and HIC test for plates of SA387Gr11CL2 HIC shall be witnessed by surveyor of SGS.

8.       Delivery conditions

The delivery conditions for plates of SA387Gr11CL2 HIC shall be Normalized(accept ACCP)+ Tempered(temperature not less than 700 C degree.)

9.       Other requirements

The other requirements for plates of SA387Gr11CL2 HIC shall be accordance with SA387/SA387M-2010.

MTC accordance with EN10204: 2004 3.1

bigPhoto
 Mr. Toby Tan

Tel: 86-769-85325956
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Gloria Steel [China (Mainland)]


Business Type:Manufacturer
City: Dongguan
Province/State: Guangdong
Country/Region: China (Mainland)

You May Like:

Product (237)